Philips TASY EMR

The U.S. Cybersecurity and Infrastructure Security Agency (CISA)
is warning of critical vulnerabilities affecting Philips Tasy
electronic medical records (EMR) system
that could be exploited
by remote threat actors to extract sensitive patient data from
patient databases.

“Successful exploitation of these vulnerabilities could result
in patients’ confidential data being exposed or extracted from
Tasy’s database, give unauthorized access, or create a
denial-of-service condition,” CISA said[1]
in a medical bulletin issued on November 4.

Used by over 950 healthcare institutions primarily in Latin
America, Philips Tasy EMR is designed as an integrated healthcare informatics[2] solution that enables
centralized management of clinical, organizational and
administrative processes, including incorporating analytics,
billing, and inventory and supply management for medical
prescriptions.

Automatic GitHub Backups

The SQL injection[3]
flaws — CVE-2021-39375 and CVE-2021-39376 — affect Tasy EMR HTML5
3.06.1803 and prior, and could essentially allow an attacker to
modify SQL database commands, resulting in unauthorized access,
exposure of sensitive information, and even the execution of
arbitrary system commands. Both security issues have been ranked
8.8 out of 10 in severity:

  • CVE-2021-39375[4]: The affected product
    allows SQL injection via the
    WAdvancedFilter/getDimensionItemsByCode FilterValue parameter.
  • CVE-2021-39376[5]: The affected product
    allows SQL injection via the CorCad_F2/executaConsultaEspecifico
    IE_CORPO_ASSIST or CD_USUARIO_CONVENIO parameter.

Prevent Data Breaches

However, it’s worth noting that taking advantage of these
vulnerabilities necessitates that the threat actor is already in
possession of the credentials that grant access to the affected
system.

“At this time, Philips has received no reports of exploitation
of these vulnerabilities or incidents from clinical use that we
have been able to associate with this problem,” the Dutch company
noted[6]
in an advisory. “Philips’ analysis has shown that it is unlikely
that this vulnerability would impact clinical use. Philips’
analysis also indicates there is no expectation of patient hazard
due to this issue.”

All healthcare providers using a vulnerable version of the EMR
system are recommended to update to version 3.06.1804. or later as
soon as possible to prevent potential real-world exploitation.